1.
J Cancer Res Ther ; 19(Supplement): S36-S40, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37147980

RESUMO

Lung cancer is one of the most common cancers in the world. Intraluminal brachytherapy (BT) is one of the most adopted treatment modalities for lung malignancies with Ir-192 source in radiotherapy. In intraluminal BT, treatment delivery is required to be very accurate and precise with respect to the plan created in the treatment planning system (TPS). The BT dosimetry is necessary for better treatment outcomes. Therefore in this review article, some relevant studies were identified and analyzed for dosimetric outcomes in intraluminal BT in lung malignancies. The dosimetry in BT for plan verification is not presently in practice, which needs to be performed to check the variation between the planned and measured doses. The necessary dosimetric work done by the various researchers in intraluminal BT such as the Monte Carlo CYLTRAN code was used to calculate and measure the dose rate in any medium. Anthropomorphic phantom was used to measure doses at some distance from the source with Thermo luminescence dosimeters (TLDs). The dosimetric influence of air passage in the bronchus was evaluated with the GEANT4 Monte Carlo method. A pinpoint chamber was used to measure and quantify the impact of inhomogeneity in wax phantom for the Ir-192 source. The Gafchromic films and Monte Carlo methods were used to find the phantom and heterogeneities, which were found to underestimate the dose for the lungs and overestimated for the bones in TPS. The exact tool to quantify the variation in planned and delivered doses should be cost-effective and easy to use possibly with tissue equivalent phantoms and Gafchromic films in lung malignancies treatment.


Assuntos
Braquiterapia , Carcinoma , Neoplasias Pulmonares , Humanos , Braquiterapia/métodos , Simulação por Computador , Radiometria , Dosagem Radioterapêutica , Neoplasias Pulmonares/radioterapia , Pulmão , Planejamento da Radioterapia Assistida por Computador/métodos , Método de Monte Carlo , Imagens de Fantasmas
2.
J Med Phys ; 42(1): 9-13, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28405102

RESUMO

Advanced radiotherapy modalities such as stereotactic radiosurgery (SRS) and image-guided radiotherapy may employ very small beam apertures for accurate localized high dose to target. Accurate measurement of small radiation fields is a well-known challenge for many dosimeters. The purpose of this study was to measure total scatter factors for stereotactic cones with plastic scintillation detector and its comparison against diode detector and theoretical estimates. Measurements were performed on Novalis Tx™ linear accelerator for 6MV SRS beam with stereotactic cones of diameter 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm. The advantage of plastic scintillator detector is in its energy dependence. The total scatter factor was measured in water at the depth of dose maximum. Total scatter factor with plastic scintillation detector was determined by normalizing the readings to field size of 10 cm × 10 cm. To overcome energy dependence of diode detector for the determination of scatter factor with diode detector, daisy chaining method was used. The plastic scintillator detector was calibrated against the ionization chamber, and the reproducibility in the measured doses was found to be within ± 1%. Total scatter factor measured with plastic scintillation detector was 0.728 ± 0.3, 0.783 ± 0.05, 0.866 ± 0.55, 0.885 ± 0.5, and 0.910 ± 0.06 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. Total scatter factor measured with diode detector was 0.733 ± 0.03, 0.782 ± 0.02, 0.834 ± 0.07, 0.854 ± 0.02, and 0.872 ± 0.02 for cone sizes of 6 mm, 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. The variation in the measurement of total scatter factor with published Monte Carlo data was found to be -1.3%, 1.9%, -0.4%, and 0.4% for cone sizes of 7.5 mm, 10 mm, 12.5 mm, and 15 mm, respectively. We conclude that total scatter factor measurements for stereotactic cones can be adequately carried out with a plastic scintillation detector. Our results show a high level of consistency within our data and compared well with published data.

3.
J Appl Clin Med Phys ; 17(3): 358-370, 2016 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-27167293

RESUMO

This study presents the basic dosimetric properties of photon beams of a Versa HD linear accelerator (linac), which is capable of delivering flattening filter-free (FFF) beams with a beam quality equivalent to the corresponding flattened beams based on comprehensive beam data measurement. The analyzed data included the PDDs, profiles, penumbra, out-of-field doses, surface doses, output factors, head and phantom scatter factors, and MLC transmissions for both FFF and flattened beams of 6 MV and 10 MV energy from an Elekta Versa HD linac. The 6MVFFF and 10MVFFF beams had an equivalent mean energy to the flattened beams and showed less PDD variations with the field sizes. Compared with their corresponding flattened beams, Dmax was deeper for FFF beams for all field sizes; the ionization ratio variations with the field size were lower for FFF beams; the out-of-field doses were lower and the penumbras were sharper for the FFF beams; the off-axis profile variations with the depths were lesser for the FFF beams. Further, the 6MVFFF and 10MVFFF beams had 35.7% and 40.9% less variations in output factor with the field size, respectively. The collimator exchange effect was reduced in the FFF mode. The head scatter factor showed 59.1% and 73.6% less variations, on average, for the 6MVFFF and 10MVFFF beams, respectively; the variations in the phantom scatter factor were also smaller. The surface doses for all beams increased linearly with the field size. The 6MVFFF and 10MVFFF beams had higher surface doses than the corresponding flattened beams for field sizes of up to 10 ×10cm2 but had lower surface doses for larger fields. Both FFF beams had lower average MLC transmissions than the flattened beams. The finding that the FFF beams were of equivalent quality to the corresponding flattened beams indicates a significant dif-ference from the data on unmatched FFF beams.


Assuntos
Filtração/instrumentação , Aceleradores de Partículas/instrumentação , Fótons , Controle de Qualidade , Proteção Radiológica , Desenho de Equipamento , Humanos , Doses de Radiação , Espalhamento de Radiação